- Remove all the connections to the battery.
- Connect the PXGateway to the BMPRO power management system CAN bus with the provided data cable. The data cable can be plugged into either CAN 1 or CAN 2 on the PXGateway.
- Connect the communication cable from the XShunt500 to the port labelled XShunt on the PXGateway.
- Connect the negative battery connection to the battery negative terminal using the connector provided or directly to the battery. It is important that the correct terminal on both the battery and the XShunt500 is used.
- Connect all negative load connections to the load negative terminal connection on the XShunt500.
- Connect all positive load connections including the XShunt500’s positive flying lead to the battery positive terminal.
- Attach the temperature sensor to an appropriate position as close to the battery as possible.
Once these connections are made the BMPRO power management system and the PXShunt500 will be connected and will start transmitting data.